International Journal of Computer Science in Sport

Validation of Velocity Measuring Devices in Velocity Based Strength Training

Authors: Thorben Menrad, Jürgen Edelmann-Nusser

To control and monitor strength training with a barbell various systems are on the consumer market. They provide the user with information regarding velocity, acceleration and trajectory of the barbell. Some systems additionally calculate the 1-repetition-maximum (1RM) of exercises and use it to suggest individual intensities for future training. Three systems were tested: GymAware, PUSH Band 2.0 and Vmaxpro (Enode Pro). The GymAware system bases on linear position transducers, PUSH Band 2.0 and Vmaxpro (Enode Pro) base on inertial measurement units. The aim of this paper was to determine the accuracy of the three systems with regard to the determination of the average velocity of each repetition of three barbell strength exercises (squat, barbell rowing, deadlift). The velocity data of the three systems were compared to a Vicon system using linear regression analyses and Bland-Altman-diagrams. In the linear regression analyses the smallest coefficient of determination (R ² .) in each exercise can be observed for PUSH Band 2.0. In the Bland-Altman diagrams the mean value of the differences in the average velocities is near zero for all systems and all exercises. PUSH Band 2.0 has the largest differences between the Limits of Agreement. For GymAware and Vmaxpro (Enode Pro) these differences are comparable.